VLDL Receptor Antibody detects endogenous levels of total VLDL Receptor.
The low density lipoprotein receptor (LDLR) gene family consists of cell surface proteins involved in receptor-mediated endocytosis of specific ligands. This gene encodes a lipoprotein receptor that is a member of the LDLR family and plays important roles in VLDL-triglyceride metabolism and the reelin signaling pathway. Mutations in this gene cause VLDLR-associated cerebellar hypoplasia. Alternative splicing generates multiple transcript variants encoding distinct isoforms for this gene.
VMA21 Antibody detects endogenous levels of VMA21.
This gene encodes a chaperone for assembly of lysosomal vacuolar ATPase. Required for the assembly of the V0 complex of the vacuolar ATPase (V-ATPase) in the endoplasmic reticulum. Associates with the V0 complex of the vacuolar ATPase (V-ATPase). MEAX is a childhood-onset disease characterized by progressive vacuolation and atrophy of skeletal muscle. It is inherited in recessive fashion, affecting boys and sparing carrier females. Onset is in childhood, and patients exhibit weakness of the proximal muscles of the lower extremities, progressing slowly to involve other skeletal muscle groups over time.
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Universal VMA. During the reaction, Universal VMA in the sample or standard competes with a fixed amount of Universal VMA on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Universal VMA. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Universal VMA in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Lascia la tua email e seleziona le aree che vuoi seguire per ricevere novita di prodotto, approfondimenti tecnici e promozioni piu pertinenti.
Puoi scegliere le macro-aree Life Science e Diagnostica oppure le singole specializzazioni.
Seleziona uno o piu ambiti di interesse per ricevere comunicazioni piu utili e mirate.
Aggiornamenti su ricerca, strumentazione e applicazioni per il mondo Life Science.
Novita, approfondimenti e promozioni per laboratori diagnostici e flussi operativi.
2025 TEMA Ricerca - All Rights Reserved.